< Back to product family

HF-S 336 TL-D II 220-240V 50/60Hz

  • Affordable, robust solution

    HF-S 336 TL-D II 220-240V 50/60Hz

    HF-S 336 TL-D II 220-240V 50/60Hz

    EAN/UPC: 872790089747000

    Order code: 913713032766

    Downloads

    Leaflet
    Size:552.5 kB

    See all downloads

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Information
Application code
II
Type version
mk1
Lamp type
TL-D
Number of lamps
3 piece/unit
Number of products on MCB (16 A type B) (nom.)
12
Automatic restart
Yes
Operating and Electrical
Input voltage
220 to 240 V
Input frequency
50 to 60 Hz
Operating frequency (nom.)
40-60 kHz
Crest factor (nom.)
1.7
Power factor 100% load (nom.)
0.98
Preheat time
1.2 s
Mains voltage performance (AC)
202-254V-8%-+6%
Mains voltage safety (AC)
198-264V-10%-+10%
Earth leakage current (max.)
0.5 mA
Inrush current width
0.35 ms
Ballast factor (nom.)
0.98
Power losses (nom.)
8.6 W
Inrush current peak (max.)
28 A
Wiring
Connector type input terminals
WAGO 744 connector
Cable capacity output wires mutual (max.)
50 pF
Connector type output terminals
WAGO 744 connector  [ Suitable for manual wiring]
Cable length hot-wiring
0.5 m
Wire strip length
8.0-9.0 mm
Dual fixture master/slave
Possible, lamp wires 2m max. length  [ Master/Slave operation possible]
Input terminal cross section
0.50-1.50 mm²
Output terminal cross section
0.50-1.50 mm²
Cable capacity cold output wires – earth (max.)
200 pF
Cable capacity hot output wires – earth (max.)
50 pF
System characteristics
Rated ballast-lamp power
36 W
Rated lamp power on TL-D
36 W
System power on TL-D
102 W
Lamp power on TL-D
95 W
Power loss on TL-D
7 W
Temperature
T ambient (max.)
50 °C
T ambient (min.)
-15 °C
T storage (max.)
80 °C
T storage (min.)
-40 °C
T case lifetime (nom.)
75 °C
T-Case maximum (max.)
75 °C
Mechanical and Housing
Housing
L 280x39x28
Emergency Operation
Nominal light output after 60 seconds
100% of EBLF
Normal operating voltage (DC)
220-240 V
Battery voltage guaranteed operation
176-275 V
Battery voltage guaranteed ignition
186-275 V
Emergency ballast lumen factor (EBLF) (nom.)
0.7 %
Nominal light output after 5 seconds
50% of EBLF
Approval and Application
Energy efficiency index
A2
EMI 9 kHz... 30 MHz
EN55015
Vibration standard
IEC68-2-6 F c
Bumps standard
IEC 68-2-29 Eb (10G/16ms)
Approval marks
F-Marking
CE marking
ENEC certificate
CCC certificate
C-Tick certificate
PSB certification
TISI marking
SIRIM approval
CB Certificate
CCC certificate
VDE-EMV certificate
Humming and noise level
< 30 dB(A)
Product Data
Full product code
872790089747000
Order product name
HF-S 336 TL-D II 220-240V 50/60Hz
EAN/UPC – product
8711500999092
Order code
913713032766
Numerator – quantity per pack
1
Numerator – packs per outer box
10
Material no. (12NC)
913713032766
Net weight (piece)
0.255 kg
Installation Diagrams
Downloads
Leaflets
Visuals
Brochures

Recently Viewed

  • Add product
     
  • Add product
     
  • Add product
     
Add product